The next generation V-Solenoid II Namur solenoid valves.
Standard features for all series:
- Robust, reliable patented 2 piston / 4 pillar poppet valve design provides bubbletight
shut-off for millions of cycles.
- 5/2 function or 3/2 function selectable via 180?turn of the patented rotary sealing
plate
- Direct NAMUR standard mounting.
- Corrosion and impact resistant glass fiber reinforced composite material.
- Low maintenance through non lubrication design.
- High air flow (Cv > 1.1) and fast response.
- Exhaust feedback - provides actuator with clean
instrument air, preventing corrosion and galling.
- Operating with air (lubricated and non
lubricated) or nitrogen.
- Wide operating temperature range:
-40oC to 50oC(-40oF to 125oF)
- Pressure range 2.5 - 8 Bar (35 - 120 psi)
- Coils easily changed with a wide selection of
voltages available.
- Coil duty cycle 100%.
- Coil can be fixed at any 90°increment
- All series CE certified
- NEMA types 1, 2, 3, 3S, 4 and 4X.
|
 |
STANDARD series
 Our STANDARD series is suitable for most applications
and offers excellent value! The very high
flow rate (Cv > 1.1) makes it the number one
choice for large actuators. We also offer speed
control valves should your actuator require slower
movement, The coils are certified to CE, CSA and
UL standards with a wide range of voltages avail
-able.
Connector: DIN industrial form.
Voltages: 12 and 24VDC, 24VAC 50/60Hz,
120VAC 50/60Hz & 240VAC 50/60Hz.
ATEX Ex series
 The ATEX EX series provides enhanced safety
features: The coils are CE certified and approved by the
Physikalisch-Technische Bundesanstalt (PTB) according
to EN 50014:1997 +A1+A2 and EN. 50028:1987
Connector: Encapsulated coil and connector with 3m
(9' 10")cable
Voltages: 12VDC, 24VDC, 24VAC 50/60Hz, 120VAC
50/60Hz & 240 VAC 50/60Hz No spacer
required for 0? 90?and 270?mounting of coil!
-  II 2 G/D EEx m II T6, T5 or T4 and IEC Ex m II
T6, T5 or T4.
-  EX II 2 G/D EEx m II T6, T5 or T4
- IEC EX m II T6, T5 or T4
Intrinsically Safe series
 If you need to maintain highest safety standards,
theINTRINSICALLY-SAFEseries will be your
choice: Intrinsically safe coils, CE and CSA certified,
FM and PTB approved for hazardous locations:
Connector: DIN EN 175301-803-A (ISO 4400)
Coil: Voltage: 24VDC, Current >37mA,
Impedance: 275 Ohm +8%, Tamb(Max) 50 .Barrier
\(not included): Voltage range: 21.6 to 28VDC,
Peak values 28VDC, 115mA, 1.6W No spacer
required for 0? 90? and 270?mounting of coil!
-  II 2G EEx ia IIC T6 or T4 approved
- IEX ia IIC T6 or T4 approved
- FM IS Class I Group A, B, C and D, Class II Group
E, F and G, Class III
EX-PROOF series
 The coils of the EX-PROOF series are CSA certified
and FM approved for hazardous locations and have
been tested according to CAN/CSA-E79-0-95 and
CAN/CSA -E79-18-95 for CSA as well as ANSI/ISAS12.00.01-
1999 and ANSI/ISA-S12.23.01-1998 for FM.
- Ex m II T4 and Division 1
- IEx ia IIC T4, Class I Group A,B,C and D,
Class II Grp. E,F and G, Class III
Connector: 1/2" metal thread connection conduit entry,
600mm(24") leads
Voltages: 12VDC, 24VDC, 24VAC 50/60Hz, 120VAC
50/60Hz & 240VAC 50/60Hz No spacer
required for 0?90? and 270?mounting of coil!
Dimensions
 |
|
Standard |
Atex Ex |
Ex Proof |
I-Safe |
| A |
125.9 |
125.3 |
113.5 |
125.3 |
| B |
66.9 |
66.7 |
65.7 |
68.7 |
| C |
53.0 |
53.0 |
53.0 |
53.0 |
| D |
18.5 |
18.5 |
18.5 |
18.5 |
| E |
27.0 |
27.0 |
27.0 |
27.0 |
| F |
78.0 |
78.0 |
78.0 |
78.0 |
| G |
62.7 |
62.7 |
62.7 |
62.7 |
| H |
17.0 |
17.0 |
17.0 |
17.0 |
| I |
15.0 |
15.0 |
15.0 |
15.0 |
| J |
24.0 |
24.0 |
24.0 |
24.0 |
| K |
17.7 |
17.7 |
17.7 |
17.7 |
|
 configuration for double acting actuators.
De-energized state, with supply to port 1,
flow is directed to port 4 and port 2 is
vented to atmosphere via port 3. |
 configuration for spring return actuators.
De-energized state, supply port 1 is blocked
and port 2 exhaust is fed back to port 4 with
excess vented to atmosphere via port 3. |
Specifications and
Order Information
Electrical (+/- 10%):
12VDC & 24VDC
24VAC,120VAC & 240VAC,50/60Hz
Duty Cycle:
100% continuous service
Insulation Class :F
Protection Class :
IP65, NEMA 1, 2, 3, 3S, 4 and 4X
Other voltages are available on request.
Construction:
Valve Body:
Reinforced Polyamide(PA)
Sealing Material:
Proprietary elastomer
Inlet Port:
1/4" NPT or G1/4" MS Zinc plated
Exhaust Port :
1/8" NPT or G1/8" MS Zinc plated
Temperature Range:
- 40°C ~ 50°C ( - 40°F ~ 125°F )
Pressure Range:
2.5 ~ 8 bar (35 ~120psi )
Response Time:
20ms(ON)40ms(OFF)
Media / Air Flow: Cv > 1.1
|
| V-Solenoid II series |
Model Code |
Voltage* |
Options |
| Standard |
VS2STD |
-XXX |
-XX |
| Atex Ex |
VS2ATEX |
-XXX |
-XX |
| Ex Proof |
VS2EX |
-XXX |
-XX |
| I-Safe |
VS2IS |
-024 |
-XX |
|
*12VDC,24VDC,24VAC,120VAC,240VAC,
Intrinsically Safe series 24VDC only.
| Options |
Code |
| Stainless Steel Bolts |
SST |
| Connector with LED |
LED |
| Exhaust Muffler 1/8" NPT |
EN8 |
| Exhaust Muffler G1/8" |
EG8 |
| Speed control valve 1/8" NPT |
SN8 |
| Speed control valve G1/8" |
SG8 |
|
Order Examples:
V-solenoid II, Standard 120VAC, no options:
VS2STD-120
V-solenoid II, ATEX Ex 240VAC, LED:
VS2ATEX-240-LED
V-solenoid II, I-Safe, Stainless Steel, LED:
VS2IS-024-SST-LED
|
|